1.
Ophthalmic Physiol Opt ; 44(3): 483-490, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38372370

RESUMO

PURPOSE: Previous research has shown that accommodation deficits are common in individuals with Down syndrome (DS), but the origin and mechanisms behind these deficits are still unknown. The aim of this study was to investigate the characteristics of different ocular structures involved in accommodation, in particular the ciliary muscle (CM), in a population of individuals with DS to further understand this deficit and its mechanisms. METHODS: Thirty-two volunteer participants of pre-presbyopic age with (n = 16) and without DS (n = 16) were recruited. Temporal and nasal images of the CM were acquired using anterior segment optical coherence tomography (AS-OCT) while participants fixated an eccentrically located target. Analysis of CM parameters was undertaken using validated semi-automated software. Axial length, anterior chamber depth, lens thickness and corneal curvature were obtained with the Topcon Aladdin Optical Biometer and Corneal Topographer. Non-cycloplegic refractive error and accommodative ability were obtained with an open-field autorefractor and dynamic retinoscopy, respectively. Independent t-tests were conducted to determine differences in CM and other anterior segment parameters between participants with and without DS. RESULTS: No significant differences were found in the CM parameters studied between participants with and without DS (p > 0.05). In contrast, significant differences were found in visual acuity (p < 0.001), accommodative response (p < 0.001) and corneal curvature (K1 p = 0.003 and K2 p < 0.001) between participants with and without DS. CONCLUSIONS: Despite having poorer accommodation, pre-presbyopic adults with DS do not have a different CM morphology to that found in typically developing adults. These findings suggest that the accommodative deficit found in this population is not due to a mechanical deficit of the CM.


Assuntos
Síndrome de Down , Cristalino , Adulto , Humanos , Cristalino/anatomia & histologia , Corpo Ciliar/diagnóstico por imagem , Corpo Ciliar/anatomia & histologia , Corpo Ciliar/fisiologia , Acomodação Ocular , Tomografia de Coerência Óptica/métodos , Músculos
2.
Expert Rev Med Devices ; 20(8): 681-690, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37402231

RESUMO

BACKGROUND: Due to the increasing use of contact lenses (CL) and the interest in ocular and body size relationships, this study aimed to compare measurements from two biometers (contact ultrasonic EchoScan US-800 and non-contact optical Lenstar LS900) with and without CL and to explore the relationship between ocular and body biometric parameters. DESIGN AND METHODS: This cross-sectional study measured ocular biometry using two biometers along with their body height and right foot length in 50 participants. Differences between biometry data from the two devices were compared and correlations between ocular and body biometric values were analyzed. RESULTS: All parameters showed interbiometric differences (p ≤ 0.030), except crystalline lens thickness during CL wear (p = 0.159). Comparing measurements with and without CL, differences were observed in axial length (p < 0.001), vitreous length measured by optical biometer (p = 0.016), and anterior chamber depth by ultrasonic biometer (p < 0.016). Lens thickness remained unaffected (p ≥ 0.190). Body height and foot length were correlated with anterior chamber depth, vitreous length, and axial length (p ≤ 0.019, r ≥ 0.330). Most biometric parameters were correlated among them using both devices (p ≤ 0.037, r ≥ 0.296). CONCLUSIONS: These biometers are not interchangeable and CL affects measurements. Body height and foot length correlate with ocular dimensions, and most ocular biometric values correlate positively.


Assuntos
Lentes de Contato , Cristalino , Humanos , Câmara Anterior/anatomia & histologia , Cristalino/anatomia & histologia , Estudos Transversais , Comprimento Axial do Olho/anatomia & histologia , Biometria , Tomografia de Coerência Óptica/métodos , Reprodutibilidade dos Testes
3.
J Optom ; 15(1): 88-99, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34736867

RESUMO

PURPOSE: To measure lens vault (LV) and to assess its correlation with various ocular parameters in healthy eyes, using for all measurements the same high-resolution swept-source optical coherence tomographer (SS-OCT). METHODS: We prospectively recruited 67 Caucasian healthy patients whose mean age was 41.9 ±â€¯12.4 years; only their right eye was included in the study. Data were all recorded with the ANTERION SS-OCT and comprised, for each patient, 5 consecutive measurements of LV, anterior chamber depth (ACD), lens thickness (LT), axial length (AL), white-to-white (WTW) distance, central corneal thickness (CCT), anterior chamber volume (ACV) and spur-to-spur (STS) distance. RESULTS: Mean LV was 0.26 ± 0.23 mm (ranging from -0.24 to 0.78 mm). Data analysis revealed a statistically significant negative correlation between LV and ACD (R=-0.80, p < 0.001), AL (R = -0.36, p = 0.002), and ACV (R = -0.68, p < 0.001), and a positive correlation between LV and LT (R = 0.67, p < 0.001), and age (R = 0.53, p < 0.001). In contrast, no statistically significant correlation was found between LV and WTW (R=-0.17, p = 0.15), CCT (R = 0.11, p = 0.36) or STS (R=-0.10, p = 0.41). CONCLUSIONS: Taking into account our findings about intra-parameter correlation levels, we believe that LV should be measured and analyzed together with other ocular parameters in clinical routine practice both for diagnosis and for some refractive surgeries.


Assuntos
Cristalino , Tomografia de Coerência Óptica , Adulto , Câmara Anterior/anatomia & histologia , Câmara Anterior/diagnóstico por imagem , Comprimento Axial do Olho , Biometria , Humanos , Cristalino/anatomia & histologia , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
5.
Sci Rep ; 11(1): 19284, 2021 09 29.
Artigo em Inglês | MEDLINE | ID: mdl-34588558

RESUMO

To examine the refractive lens power (RLP) and lens thickness and their associated factors in children from North-Western China. Children from two schools (primary school and junior high school) in the North-Western Chinese province of Qinghai underwent a comprehensive ophthalmic examination including biometry and cycloplegic refractometry. The RLP was calculated using Bennett's equation. The study included 596 (77.9%) individuals (mean age: 11.0 ± 2.8 years; range: 6-16 years) with a mean axial length of 23.65 ± 1.24 mm (range: 20.02-27.96 mm). Mean lens thickness was 3.30 ± 0.16 mm (range: 2.85-3.99 mm) and mean RLP was 24.85 ± 1.98D (range: 19.40-32.97). In univariate analysis, girls as compared to boys had a significantly thicker lens and greater RLP, shorter axial length, smaller corneal curvature radius and shorter corneal curvature radius (all P < 0.001). Both sexes did not differ significantly in refractive error (P = 0.11) and corneal thickness (P = 0.16). RLP was positively associated with refractive error (correlation coefficient r = 0.33; P < 0.001) and lens thickness (r = 0.62; P < 0.001) and negatively with axial length (r = - 0.70; P < 0.001). In univariate analysis, RLP decreased significantly with older age in the age group from age 6-13, while it plateaued thereafter, with no significant difference between boys and girls. In multivariate regression analysis, a higher RLP was associated with younger age (P < 0.001; standard regression coefficient ß = - 0.07), female sex (P < 0.001; ß = - 0.08), shorter axial length (P < 0.001; ß = - 0.48) and higher lens thickness (P < 0.001; ß = 0.42). In Chinese children, RLP with a mean of 24.85 ± 1.98D decreases with older age, male sex, longer axial length, and thinner lens thickness. Changes in RLP and axial length elongation are important players in the emmetropization and myopization.


Assuntos
Cristalino/anatomia & histologia , Refração Ocular/fisiologia , Adolescente , Fatores Etários , Biometria , Criança , China , Estudos Transversais , Feminino , Humanos , Cristalino/fisiologia , Masculino , Erros de Refração/etiologia , Erros de Refração/fisiopatologia , Refratometria , Fatores Sexuais
6.
PLoS One ; 16(9): e0256975, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34499644

RESUMO

Lens and skin fluorescence are related to the systemic accumulation of advanced glycation end products, which is accelerated in diabetes. We have examined lens fluorescence and skin fluorescence in healthy adult twins. The study enrolled twins aged median 59 years from a national population-based registry. Diabetic individuals were excluded from analysis. The interrelatedness between fluorescence parameters and relations between fluorescence and age, current HbA1c and smoking pack years were examined using correlation tests and mixed model linear regression analyses. Broad-sense heritability was analyzed and compared for lens fluorescence, skin fluorescence and HbA1c. Lens fluorescence and skin fluorescence were crudely interrelated (R = 0.38). In linear regression analyses, age explained a larger fraction of the variance in lens fluorescence (R2 = 32%) than in skin fluorescence (R2 = 20%), whereas HbA1c explained smaller variance fractions (R2 = 3% and 8%, respectively) followed by smoking pack years (4% and 3%, respectively). In multivariate analyses, age, HbA1c and smoking pack years combined explained more of the variance in lens fluorescence (R2 = 35%) than in skin fluorescence (R2 = 21%), but the influence of HbA1c on lens fluorescence was not statistically significant (p = .2). Age-adjusted broad-sense heritability was 85% for lens fluorescence, 53% for skin fluorescence and 71% for HbA1c in best fitting heritability models. Both fluorescence parameters increased with age, current glycemia and cumulative smoking. Lens fluorescence was found to be a predominantly heritable trait, whereas skin fluorescence was more influenced by environmental factors and closer related to current glycemia. The results suggest that skin fluorophores have a faster turn-over than lens fluorophores.


Assuntos
Olho/anatomia & histologia , Cristalino/anatomia & histologia , Fenômenos Fisiológicos Oculares/genética , Pele/anatomia & histologia , Pré-Escolar , Estudos de Coortes , Dinamarca/epidemiologia , Feminino , Fluorescência , Humanos , Lactente , Cristalino/metabolismo , Masculino , Pessoa de Meia-Idade , Pele/metabolismo , Estudos em Gêmeos como Assunto , Gêmeos Monozigóticos/genética
7.
Sci Rep ; 11(1): 14590, 2021 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-34272413

RESUMO

In retinoblastoma, accurate segmentation of ocular structure and tumor tissue is important when working towards personalized treatment. This retrospective study serves to evaluate the performance of multi-view convolutional neural networks (MV-CNNs) for automated eye and tumor segmentation on MRI in retinoblastoma patients. Forty retinoblastoma and 20 healthy-eyes from 30 patients were included in a train/test (N = 29 retinoblastoma-, 17 healthy-eyes) and independent validation (N = 11 retinoblastoma-, 3 healthy-eyes) set. Imaging was done using 3.0 T Fast Imaging Employing Steady-state Acquisition (FIESTA), T2-weighted and contrast-enhanced T1-weighted sequences. Sclera, vitreous humour, lens, retinal detachment and tumor were manually delineated on FIESTA images to serve as a reference standard. Volumetric and spatial performance were assessed by calculating intra-class correlation (ICC) and dice similarity coefficient (DSC). Additionally, the effects of multi-scale, sequences and data augmentation were explored. Optimal performance was obtained by using a three-level pyramid MV-CNN with FIESTA, T2 and T1c sequences and data augmentation. Eye and tumor volumetric ICC were 0.997 and 0.996, respectively. Median [Interquartile range] DSC for eye, sclera, vitreous, lens, retinal detachment and tumor were 0.965 [0.950-0.975], 0.847 [0.782-0.893], 0.975 [0.930-0.986], 0.909 [0.847-0.951], 0.828 [0.458-0.962] and 0.914 [0.852-0.958], respectively. MV-CNN can be used to obtain accurate ocular structure and tumor segmentations in retinoblastoma.


Assuntos
Olho/anatomia & histologia , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Descolamento Retiniano/diagnóstico por imagem , Doenças Retinianas/diagnóstico por imagem , Neoplasias da Retina/diagnóstico por imagem , Retinoblastoma/diagnóstico por imagem , Automação/métodos , Criança , Pré-Escolar , Aprendizado Profundo , Feminino , Humanos , Lactente , Recém-Nascido , Cristalino/anatomia & histologia , Imageamento por Ressonância Magnética , Masculino , Redes Neurais de Computação , Estudos Retrospectivos , Esclera/anatomia & histologia , Corpo Vítreo/anatomia & histologia
8.
Opt Express ; 29(11): 16105-16117, 2021 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-34154180

RESUMO

Using the internally placed elastic membrane and multi-chamber configuration, we designed a digitized mini optofluidic element for fast switching between refractive and diffractive states of preset optical powers. Relief surface was used in the diffractive state. We applied finite element analysis to establish membrane mechanical characteristics for switching at the force level produced by the ocular elements such as ciliary muscle or lower eyelid at eye downgaze. The prototypes were made to demonstrate proof-of-concept. Membrane conformance to the diffractive grooves and imaging quality were demonstrated. The analysis supported switching under the force level exerted by the ocular elements supporting the digitized optofluidic element potential for presbyopia correction by ophthalmic lenses.


Assuntos
Óculos , Cristalino/anatomia & histologia , Lentes Intraoculares , Óptica e Fotônica , Presbiopia/terapia , Humanos
9.
Exp Eye Res ; 209: 108653, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34097905

RESUMO

It is well known that human crystalline lens shape, dimensions and optical properties change throughout life and influence whole eye refraction. However, it is not clear if lens properties are associated with other ocular parameters. The purpose of the present study was to investigate the relationship of corneal and external globe dimensions with adult lens diameter (LD), lens thickness (LT) and lens power (LP) in order to determine if external factors influence lens properties. Postmortem human eyes (n = 66, age = 20-78 years) were obtained from the Ramayamma International Eye Bank, Hyderabad, India. Globe antero-posterior length (GAPL) and mean (average of horizontal and vertical) diameters of cornea (MCD) and globe (MGD) were measured using digital calipers. Eyes were dissected to produce ocular structures that contain the lens maintained in its accommodating framework, including intact zonules, ciliary body and sections of sclera. Specimens were mounted in a mechanical lens stretching system. LD, LT and LP were measured using high magnification retro-illumination photography, slit illumination photography and Scheiner principle-based optical system respectively in the unstretched (accommodated) state. Relationships between external globe and corneal dimensions and LD, LT or LP were assessed by multiple regression analysis. Age (0.012 ± 0.003 mm/year; p<0.001) and GAPL (0.185 ± 0.045 mm/mm; p<0.001) were significant (p<0.0001) predictors of LD. After adjusting for age-related increases, LD appears to be positively correlated with GAPL. Age (0.010 ± 0.004 mm/year; p = 0.009) and GAPL (-0.143 ± 0.060 mm/mm; p = 0.02) were significant (p = 0.001) predictors of LT. After adjusting for the age-related increase, LT appears to be negatively correlated with GAPL. Only age was a significant predictor of LP (-0.26 ± 0.04 D/year; p<0.001). The results suggest that, apart from aging, lens diameter and thickness are dependent on the anteroposterior length of the eye globe. Lens power is not influenced by globe dimensions.


Assuntos
Acomodação Ocular/fisiologia , Envelhecimento/fisiologia , Biometria/métodos , Córnea/anatomia & histologia , Olho/anatomia & histologia , Cristalino/anatomia & histologia , Refração Ocular/fisiologia , Adulto , Idoso , Córnea/crescimento & desenvolvimento , Olho/crescimento & desenvolvimento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Adulto Jovem
10.
Radiat Environ Biophys ; 60(3): 421-430, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33966106

RESUMO

As part of the wider interest in the effects of ionizing radiation on non-human biota, this investigation was carried out to study early radiation damage to the eye-lenses of rainbow trout. Lenses were cultured and irradiated to doses of 1.1 Gy and 2.2 Gy with low-energy X-rays of 40 kV. Laser focal analysis was used to track changes in focal lengths across the lenses post-irradiation. Changes in focal length variability (FLV) were measured to determine whether this could give an indication of the early effects of radiation on lens health. No statistically significant differences in FLV between the control and irradiated lenses within 10 days post-irradiation were observed. FLV was found to be 0.09 ± 0.02 mm for 2.2 Gy lenses, 0.06 ± 0.01 mm for 1.1 Gy lenses, and 0.11 ± 0.02 mm for control lenses at the end of the observation period.


Assuntos
Cristalino/efeitos da radiação , Animais , Cristalino/anatomia & histologia , Oncorhynchus mykiss , Raios X
11.
Sci Rep ; 11(1): 9639, 2021 05 05.
Artigo em Inglês | MEDLINE | ID: mdl-33953252

RESUMO

The purpose of this study was to investigate how the mechanical properties and geometry of the lens influence the changes in lens shape during accommodation. To do so, ex vivo stretching tests of the isolated lens were simulated via finite element analysis. In these tests, the lens is stretched from the accommodated state to the non-accommodated state. Several key characteristics of the lens were studied: the stiffness gradient of the lens material, the distribution of the capsule thickness, the mechanical properties of the capsule and the material comprising the lens, nucleus and cortex, and the influence of two different age-related lens geometries (17 and 29 y/o subjects). To determine the effects on the changes in lens shape during accommodation, changes in the anterior and posterior radius, the lens and nucleus thicknesses and the equatorial lens diameter were analysed. The results suggest that multiple factors exert statistically significant influences on how the lens changes its shape, but two factors predominate over the rest: the stiffness ratio between the nucleus and cortex and the stiffness of the capsule, specifically the posterior surface.


Assuntos
Acomodação Ocular/fisiologia , Cristalino/anatomia & histologia , Adolescente , Adulto , Fenômenos Biomecânicos/fisiologia , Elasticidade , Análise de Elementos Finitos , Humanos , Cristalino/fisiologia , Modelos Biológicos
12.
Exp Eye Res ; 207: 108578, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33864786

RESUMO

OBJECTIVE: To compare the biometric parameters provided by A-scan ultrasonography and the Lenstar optical biometer in guinea pig eyes, including anterior segment depth (ASD), lens thickness (LT), vitreous chamber depth (VCD), and axial length (AL), and differences of them between treated form deprivation (FD) eyes and untreated fellow eyes after 4 weeks of FD. METHODS: Three-week-old guinea pigs (N = 41) were subjected to biometric measurements before monocular FD (baseline) and after a 4-week FD. Statistical analyses including within-subject standard deviation (SDwithin), coefficient of variation (CV), and intraclass correlation coefficient (ICC), used to evaluate repeatability for both the A-scan ultrasonography and the Lenstar individually, and correlation and Bland-Altman analyses were used to assess agreement between the two methods. The absolute values of ASD, LT, VCD and AL as measured by the two devices were compared, and the differences of them between treated (T) and untreated fellow (F) eyes (ΔASD, ΔLT, ΔVCD and ΔAL) (Δ = T-F) were compared between the two devices after 4 weeks of FD. RESULTS: Measurements by the Lenstar (ICC: 0.923-0.994) were more repeatable than A-scan ultrasonography (ICC: 0.825-0.870). There was a high correlation for AL (r = 0.851, P < 0.001), a moderate correlation for VCD (r = 0.571, P < 0.001) and LT (r = 0.423, P < 0.001), and a low correlation for ASD (r = 0.230, P < 0.01) between the two devices. The values for ASD, VCD and AL measured by A-scan ultrasonography were larger than those measured by the Lenstar (all, P < 0.001), while LT provided by A-scan ultrasonography was much smaller than that of the Lenstar (P < 0.001). Bland-Altman plots showed poor agreement of absolute values of the four parameters between the two devices. Moreover, there was a high correlation between both methods for ΔAL (r = 0.704, P < 0.001), a moderate correlation for ΔVCD (r = 0.534, P < 0.001) and ΔASD (r = 0.574, P < 0.001), and no correlation for ΔLT (r = 0.303, P = 0.054). The ΔASD, ΔLT, and ΔAL measurements obtained by A-scan ultrasonography were greater than those obtained by the Lenstar (all, P < 0.001), while ΔVCD was mildly smaller using A-scan ultrasonography (P < 0.05). Bland-Altman plots illustrated there is good agreement of ΔAL, ΔVCD, ΔASD, and ΔLT between the two devices. CONCLUSIONS: The Lenstar exhibited better repeatability and provided smaller measurements for AL, VCD and ASD than A-scan ultrasonography. Furthermore, a high correlation and a good agreement for the ΔAL was observed between the two devices after a period of FD. In summary, the two devices cannot replace each other directly to obtain absolute values of ASD, LT, VCD and AL, but the Lenstar still can serve as an option in measuring ΔAL between eyes in guinea pig myopia model.


Assuntos
Segmento Anterior do Olho/anatomia & histologia , Comprimento Axial do Olho/anatomia & histologia , Biometria/instrumentação , Interferometria/métodos , Cristalino/anatomia & histologia , Ultrassonografia/métodos , Corpo Vítreo/anatomia & histologia , Animais , Cobaias , Luz , Masculino , Reprodutibilidade dos Testes
13.
Sci Rep ; 11(1): 6688, 2021 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-33758264

RESUMO

To quantitatively analyze changes in the inner components of the human crystalline lens during accommodation in adults. Eyes of 23 subjects were sequentially examined using CASIA2 Optical Coherence Tomography under 0D, - 3D and - 6D accommodation states. The anterior chamber depth (ACD), anterior and posterior crystalline lens radius of the curvature (ALRC and PLRC) were obtained using built-in software. The lens thickness (LT), lenticular nucleus thickness (NT), anterior cortex thickness (ACT), posterior cortex thickness (PCT), anterior and posterior lenticular nucleus radius of the curvature (ANRC and PNRC), anterior and posterior lenticular nucleus vertex (ANV and PNV) were quantified manually with the Image-pro plus software. During accommodation, the ACD became significantly shallower and LT significantly increased. For changes in the lens, the ALRC decreased by an average magnitude (related to accommodative stimuli) 0.44 mm/D, and PLRC decreased 0.09 mm/D. There was no difference for the ACT and PCT in different accommodation states. For lenticular nucleus response, NT increased on average by 30 µm/D. Both the ANRC and PNRC decreased on average by 212 µm/D and 115 µm/D respectively. The ANV moved forward on average by 0.07 mm under - 3D accommodative stimuli and 0.16 mm for - 6D. However, there was no statistically significant difference between different accommodation states in the PNV movement. Under accommodation stimulation, lens thickness changed mainly due to the lenticular nucleus, but not the cortex. For the lenticular nucleus, both the ANRC and PNRC decreased and ANRC changed the most. The anterior surface of the nucleus moved forward while the posterior surface of the nucleus moved backward but only slightly.


Assuntos
Acomodação Ocular , Cristalino/fisiologia , Adulto , Fatores Etários , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador , Cristalino/anatomia & histologia , Cristalino/diagnóstico por imagem , Tomografia de Coerência Óptica
14.
Exp Eye Res ; 205: 108481, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33545121

RESUMO

There have been many studies on lens properties in specific populations (e.g. in China, Europe, Singapore, etc.) some of which suggest there may be differences between populations. Differences could be caused by ethnic or environmental influences or experimental procedures. The purpose of this study is to evaluate if any differences exist between Indian and European populations in the central geometric and full shape properties of human lenses. Two custom-developed spectral domain optical coherence tomography systems were used to acquire the crystalline lens geometry: one in India (69 lenses from 59 donors) and the other in Spain (24 lenses from 19 donors). The steps for obtaining accurate 3-D models from optical coherence tomography raw images comprised of image segmentation, fan and optical distortion correction, tilt removal and registration. The outcome variables were lens equatorial diameter, lens thickness, anterior and posterior lens thicknesses and their ratio, central radius of curvature of the anterior and posterior lens surfaces, lens volume and lens surface area. A mixed effects model by maximum likelihood estimation was used to evaluate the effect of age, population and their interaction (age*population) on lens parameters. After adjusting for age, there were no population differences observed in anterior and posterior radii of curvature, equatorial diameter, lens thickness, anterior and posterior lens thicknesses and their ratio, volume and surface area (all p ≥ 0.08). There was also no effect of the interaction term on anterior and posterior radii of curvature, equatorial diameter, lens thickness, anterior and posterior lens thicknesses and their ratio, volume and surface area (all p ≥ 0.06). All central geometric and full shape parameters appeared to be comparable between the European and Indian populations. This is the first study to compare geometric and full shape lens parameters between different populations in vitro.


Assuntos
Povo Asiático/genética , Cristalino/anatomia & histologia , Forma das Organelas/genética , População Branca/genética , Adulto , Biometria , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional/métodos , Índia , Cristalino/diagnóstico por imagem , Funções Verossimilhança , Pessoa de Meia-Idade , Modelos Estatísticos , Tomografia de Coerência Óptica/métodos , Adulto Jovem
15.
Am J Ophthalmol ; 225: 147-156, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33385370

RESUMO

PURPOSE: To characterize crystalline lens dimensions derived from in vivo spectral-domain optical coherence tomography (SD-OCT) and identify associations among these parameters, ocular biometry, and age. METHODS: In this retrospective study, lens thickness (LT), lens diameter (LD), and lens volume (LV) were measured intraoperatively using SD-OCT in 293 eyes undergoing lens surgery. Correlations among LT, LD, LV, age, axial length (AL), and anterior chamber depth (ACD) were analyzed. Multiple regression analysis was performed to determine whether a combination of biometric data could predict LD and LV. RESULTS: Wide variations were observed in LT (3.6-5.7 mm), LD (7.5-11.9 mm), and LV (119.9-312.4 mm3) of aging eyes. Correlations among the 3 lens dimensions were statistically significant (LV-LT: r = 0.785; P < .001; LV-LD: r = 0.696; P < .001; and LT-LD: r = 0.121; P = .039). With age, the correlation coefficients of LT, LD, and LV were 0.526, 0.326, and 0.573, respectively (P < .001). Although there was significant correlation of AL with LT (r = -0.137; P = .002) and LD (r = 0.268; P < .001), it was not significant with LV (r = 0.084; P = .15). Subgroup analysis revealed that 19.8% of long eyes had LD >1 standard deviation (SD) above and that 5.2% had LD <1 SD below the mean LD. CONCLUSIONS: Dimensions of the aging lens vary considerably and are most accurately characterized by direct measurement of LT, LD, and LV, rather than making assumptions based on AL. These findings challenge historically proposed relationships between LD and AL and represent a normative dataset of contemporary geometric features of the aging lens, possibly aiding in surgical decision making and future developments in lens surgery.


Assuntos
Envelhecimento/fisiologia , Cristalino/anatomia & histologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Câmara Anterior/anatomia & histologia , Comprimento Axial do Olho/anatomia & histologia , Biometria , Feminino , Humanos , Período Intraoperatório , Cristalino/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia de Coerência Óptica , Adulto Jovem
16.
Exp Eye Res ; 203: 108394, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33310058

RESUMO

Micro-CT visualization allows reconstruction of eye structures with the resolution of light microscopy and estimation of tissue densities. Moreover, this method excludes damaging procedures and allows further histological staining due to the similar steps in the beginning. We have shown the feasibility of the lab-based micro-CT machine usage for visualization of clinically important compartments of human eye such as trabecular outflow pathway, retina, iris and ciliary body after pre-treatment with iodine in ethanol. We also identified the challenges of applying this contrasting technique to lens, cornea, and retina and proposed alternative staining methods for these tissues. Thereby this work provides a starting point for other studies for imaging of human eyes in normal and pathological conditions using lab-based micro-CT systems.


Assuntos
Enucleação Ocular , Olho/anatomia & histologia , Olho/diagnóstico por imagem , Microtomografia por Raio-X , Câmara Anterior/anatomia & histologia , Câmara Anterior/diagnóstico por imagem , Segmento Anterior do Olho/anatomia & histologia , Segmento Anterior do Olho/diagnóstico por imagem , Estudos de Viabilidade , Humanos , Imageamento Tridimensional , Cristalino/anatomia & histologia , Cristalino/diagnóstico por imagem , Retina/anatomia & histologia , Retina/diagnóstico por imagem
17.
Exp Eye Res ; 202: 108334, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33121973

RESUMO

There is a great need for accurate biometric data on human lenses. To meet this, a compact tabletop optical comparator, the minishadowgraph, was built for measuring isolated eye lens shape and dimensions while the lens was fully immersed in supporting medium. The instrument was based around a specially designed cell and an illumination system which permitted image recording in both sagittal and equatorial (coronal) directions. Data were acquired with a digital camera and analyzed using a specially written MATLAB program as well as by manual measurements in image analysis software. The possible effect of lens orientation and gravity on the dimensions was examined by measuring dimensions with anterior or posterior surfaces up and by measuring lenses with calipers after removal from the minishadowgraph cell. Dimensions, curvatures and shape factors were obtained for 134 fully accommodated lenses ranging in age from birth to 88 years postnatal. Of these, 41 were from donors aged under 20 years, ages which are generally of limited availability. Thickness and diameter showed the same age-related trends described in previous studies but, for the lenses measured in air, age-dependent differences were observed in thickness (-5 to 0%) and diameter (+5 to 0%), consistent with gravitational sag. Anterior and posterior radii of curvature of the central 3 or 6 mm, depending on lens diameter, increase with age, with the anterior increase greater than the posterior. The anterior surface shape of the neonatal lens is that of a prolate ellipse and the posterior, an oblate ellipse. Both surfaces become hyperbolic after age 20. The data presented here on dimensions, shape and sagging will be of great value in assessing age-related changes in the optical and mechanical performance of the lens. In particular, the comprehensive data set from donors aged under 20 years provides a unique and valuable insight to the changes in size and shape during the early dynamic growth period of the lens.


Assuntos
Envelhecimento/fisiologia , Cristalino/anatomia & histologia , Acomodação Ocular/fisiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biometria , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Fotogrametria , Doadores de Tecidos
18.
Invest Ophthalmol Vis Sci ; 61(14): 7, 2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-33270843

RESUMO

Purpose: To reveal age-related changes of the human crystalline lens by using high-spatial resolution T1-weighted brain magnetic resonance imaging of patients under general anesthesia. Methods: We retrospectively identified 47 children (2-17 years) and 30 adults (18-70 years) without diabetes or eye disease, who required brain magnetic resonance imaging examinations under general anesthesia between 2012 and 2019. Normalized signal intensity of the crystalline lens and vitreous body, as well as equatorial diameter and axial thickness of the lens were assessed by using a three-dimensional T1-weighted magnetization prepared rapid acquisition gradient echo sequence of the brain with 0.9-mm spatial resolution. Patient dossiers were reviewed to record indication for magnetic resonance imaging examination and hypertension. Results: Advancing age was significantly correlated with increasing equatorial diameter of the infantile lens (r = 0. 74; 95% confidence interval, 0.58-0.85; P < .0001) and increasing crystalline lens signal intensity of the adult lens (r = 0.38; 95% confidence interval, 0.02-0.65; P = .0382), which remained significant after accounting for potential confounding variables. There was no significant correlation between age and axial thickness or vitreous body signal intensity in the children and adult cohort. Conclusions: The present study demonstrated that advancing age was significantly correlated with an increasing equatorial diameter of the infantile lens and with increasing crystalline lens signal intensity of the adult lens. These normative data can contribute to our understanding of age-related changes in eye health and function, especially in regard to the emmetropization process and should also be taken into account when investigating lens pathologies.


Assuntos
Encéfalo/diagnóstico por imagem , Cristalino/anatomia & histologia , Imageamento por Ressonância Magnética , Neuroimagem , Adolescente , Adulto , Fatores Etários , Idoso , Criança , Pré-Escolar , Feminino , Humanos , Imageamento Tridimensional , Cristalino/crescimento & desenvolvimento , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
19.
Ophthalmic Physiol Opt ; 40(5): 584-594, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32654281

RESUMO

PURPOSE: Near work has been linked with myopia development; however, the underlying mechanism remains unclear. Small increases in axial length during accommodation have previously been reported in adults, and therefore, this study aimed to examine if accommodation-induced changes in ocular biometry also occur in school-aged children. METHODS: A range of ocular biometric measurements were captured during brief accommodation tasks at four demands (0, 3, 6, and 9 D), in a group of 87 non-myopic, school-aged children using a Badal optometer mounted to a non-contact optical biometer (Zeiss IOLMaster 700, https://www.zeiss.com/meditec/int/product-portfolio/optical-biometers/iolmaster-700.html). Reliable biometry measurements and active accommodation were observed for 76 participants who were included in the analysis. The average central corneal thickness (CCT), anterior chamber depth (ACD), crystalline lens thickness (LT), anterior segment length (ASL), vitreous chamber depth (VCD), and axial length (AL) were determined for each accommodation demand. Raw measurements of AL and VCD were corrected to account for the effect of LT changes during accommodation. RESULTS: On average, AL increased with increasing levels of accommodation (p = 0.005). The mean (SEM, standard error of the mean) AL increase from 0 D to the 3, 6, and 9 D demands was 4 (1), 8 (1), and 15 (2) µm, respectively. All other biometric parameters, except CCT, changed significantly during accommodation. LT and ASL increased, and ACD and VCD decreased significantly with increasing accommodation (all p ≤ 0.02). A longer baseline AL was associated with greater levels of accommodation-induced axial elongation at the 9 D demand (p < 0.0001). CONCLUSIONS: AL increased significantly during accommodation in children, consistent with previous findings in adults up to a 6 D demand. AL continued to increase for higher levels of accommodation (9 D demand), which children may experience during near tasks. These findings provide further insights into potential mechanisms linking near work, axial elongation, and myopia development. However, no myopic children participated in this experiment; therefore, further research is required.


Assuntos
Acomodação Ocular/fisiologia , Segmento Anterior do Olho/diagnóstico por imagem , Comprimento Axial do Olho/anatomia & histologia , Biometria/métodos , Córnea/anatomia & histologia , Cristalino/anormalidades , Segmento Anterior do Olho/fisiologia , Criança , Pré-Escolar , Feminino , Humanos , Cristalino/anatomia & histologia , Cristalino/fisiologia , Masculino , Valores de Referência , Tomografia de Coerência Óptica
20.
Expert Rev Med Devices ; 17(6): 591-597, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32425075

RESUMO

PURPOSE: To assess the repeatability of ocular biometric parameters using a high-resolution imaging device. METHODS: 74 healthy right eyes were included in this study. Five-repeated measurements were taken with ANTERION high-resolution swept-source optical coherence tomographer (SS-OCT) to measure: corneal thickness (central and at 2, 4 and 6-mm diameters), aqueous depth (AD), lens thickness (LT), anterior chamber volume (ACV), axial length (AL), and pupil (diameter and position). The intrasubject standard deviation (Sw), coefficient of repeatability (CoR) and intraclass correlation coefficient (ICC) were calculated. Bland-Altman method was applied to analyze the difference between the first and the last measurement. The average and the difference between both measurements were calculated for all parameters. RESULTS: We have not found statistically significant differences between repeated measurements (p > 0.05). The mean difference for corneal thickness was between -0.08 and 0.28 µm. For AD and LT was 0.004 and -0.004 µm, respectively. ACV mean difference was -0.03 mm3 and for AL was 0.001 mm. Pupil diameter and position mean differences ranged between -0.008 and 0.009 mm. Overall, most ocular parameters had a Sw <1 and a CoR <2 in their respective units, and an ICC >0.92. CONCLUSIONS: The ANTERION high-resolution SS-OCT device provides good repeatability for different ocular biometric measurements.


Assuntos
Biometria/instrumentação , Olho/anatomia & histologia , Tomografia de Coerência Óptica/instrumentação , Adulto , Idoso , Câmara Anterior/anatomia & histologia , Feminino , Humanos , Cristalino/anatomia & histologia , Masculino , Pessoa de Meia-Idade , Pupila/fisiologia , Reprodutibilidade dos Testes , Adulto Jovem